Question Title

1. Register (Required.)

Question Title

2. Questions 3-12 relate to GENERAL Carrier equipment and general refrigeration principles. Do you understand? (Required.)

Question Title

3. Long line accessories are required when equivalent line length exceeds how many feet?

Question Title

4. Factory condensing units come charged for how many equivalent feet of lineset

Question Title

5. When installing a Heat Pump, the filter drier must be

Question Title

6. When installing a Liquid Line Solenoid Valve for a Heat Pump, the solenoid

Question Title

7. EXVs are what?

Question Title

8. To charge by subcooling, outdoor ambient temperatures must be

Question Title

9. To charge by subcooling, the indoor ambient temperatures must be

Question Title

10. If temperatures are inadequate for charging by subcooling

Question Title

11. If you were choosing to size a unit to the heating load or to the cooling load, what else must you consider

Question Title

12. Additional refrigerant charge is listed as

Question Title

13. Questions 14-23 pertain to current Infinity Systems, do you understand (Required.)

Question Title

14. Communication wire from the air source to the outdoor unit uses

Question Title

15. The manuals will tell you to wait 10 minutes after power down before handling the circuitry, why?

Question Title

16. The PEV does what?

Question Title

17. The purpose of Check Out Mode is to

Question Title

18. Altitude adjustments are located in which Setup control menu

Question Title

19. When testing resistances of ECM or Inverter driven motor windings, you want to see what?

Question Title

20. If a circuit board gets changed in a fully communicating system, you must (select all that apply)

Question Title

21. Completing the Full Installation through the controller is an advisable course of action during many control related service calls

Question Title

22. If you used Check Out Mode to enable Heat Pump Heating and outside temps are over the max heating OAT, will the unit run?

Question Title

23. Pump down is a feature in the Infinity Control that is required, if pump down operation is desired

Question Title

24. Questions 25-39 pertain to the 5 stage VNA9/8 models, do you understand (Required.)

Question Title

25. Max equivalent line length allowed is

Question Title

26. Long Line accessories are required at what equivalent length

Question Title

27. This product is qualified for Low Ambient Cooling

Question Title

28. Minimum outdoor temp for heating is

Question Title

29. What type of compressor is used in this equipment

Question Title

30. If controlled by a conventional thermostat, the minimum outdoor temp for cooling is

Question Title

31. If controlled by an Infinity control, the minimum outdoor temp for cooling is

Question Title

32. Maximum outdoor heating temperature is

Question Title

33. The control panel consists of (select all that apply)

Question Title

34. These units contain a Discharge Temperature thermistor

Question Title

35. These units contain a Discharge Pressure Transducer

Question Title

36. The crankcase heater is a replaceable component

Question Title

37. All codes will always blink on the AOC board

Question Title

38. The SEER rating of this equipment is

Question Title

39. This equipment can calculate Superheat and Subcooling

Question Title

40. Questions 41-55 pertain to the Fully Modulating VNA6/4, do you understand? (Required.)

Question Title

41. Can this equipment be ran permanently with a conventional thermostat?

Question Title

42. This equipment has a Discharge Temperature Thermistor

Question Title

43. This equipment has a Discharge Pressure Transducer

Question Title

44. This equipment only comes with a Rotary Compressor

Question Title

45. One difference between the 5 ton and other sizes is

Question Title

46. What are the lineset length rules (select all that apply)

Question Title

47. What is the SEER rating of the equipment

Question Title

48. The Bluetooth module (select all that apply)

Question Title

49. How many digits are the Alert Codes

Question Title

50. Minimum outdoor temp for heating is

Question Title

51. The Maximum outdoor temp in heating is

Question Title

52. The Maximum outdoor temp in cooling is

Question Title

53. This product is qualified for Low Ambient Cooling

Question Title

54. The control box consist of (select all that apply)

Question Title

55. The crankcase heater is a replaceable component

T