Bryant Variable Speed Certification Question Title * 1. Register Question Title * 2. Questions 3-12 relate to GENERAL Bryant equipment and general refrigeration principles. Do you understand? Yes Question Title * 3. Long line accessories are required when equivalent line length exceeds how many feet? 100 200 250 80 Question Title * 4. Factory condensing units come charged for how many equivalent feet of lineset 25 ft 15 ft 250 ft 0 ft Question Title * 5. When installing a Heat Pump, the filter drier must be Biflow Turned upside down Valved off Unidirectional Question Title * 6. When installing a Liquid Line Solenoid Valve for a Heat Pump, the solenoid Mounts at the Indoor Coil Mounts within 2 ft of the outdoor unit Must be a smaller pipe size Must be a larger pipe size Question Title * 7. EXVs are what? Another way of saying solenoid Another way of saying TXV Motor driven metering devices Not important Question Title * 8. To charge by subcooling, outdoor ambient temperatures must be At 0 Between 65 and 105 Less than 65 or greater than 105 Below 0 Question Title * 9. To charge by subcooling, the indoor ambient temperatures must be Between 65 and 80 Below 0 At 0 Room temperature Question Title * 10. If temperatures are inadequate for charging by subcooling You should charge by lineset length and return when temperatures are adequate You cannot run or add refrigerant to the equipment at all You can let the system run regardless of charge You must cover the equipment until you return Question Title * 11. If you were choosing to size a unit to the heating load or to the cooling load, what else must you consider Only the Manual J calculation for the home How much money the customer wants to spend on accessories The ductwork limitations How many people live in the house Question Title * 12. Additional refrigerant charge is listed as Simply based on superheat Simply based on subcooling 0.6 oz/ft, but should be double checked 1 extra pound per 10 ft Question Title * 13. Questions 14-23 pertain to current Evolution Systems, do you understand Yes Question Title * 14. Communication wire from the air source to the outdoor unit uses C, D A, B, and sometimes C B, D A, B, C, D Question Title * 15. The manuals will tell you to wait 10 minutes after power down before handling the circuitry, why? You don't, the factory is just making rules Not all disconnects work correctly and powering down for 10 minutes will trip a breaker if something is wrong Since AC voltage flows both ways on a wire, you have to wait for the opposite direction to flow out The AC voltage charges capacitors at a higher voltage than your meter reads at the incoming lugs. So the capacitors need time to drain Question Title * 16. The PEV does what? Soft start the compressor Prevent the system from running when the pressures are equal Equalizes the pressures from the low and high sides Keep refrigerant pressures isolated from low to high sides Question Title * 17. The purpose of Check Out Mode is to Establish communication to the whole system Lock the system permanently into modes so others may be disabled Establish communication between the indoor and outdoor units Briefly run all components to observe operation in requested modes Question Title * 18. Altitude adjustments are located in which Setup control menu In the Advanced Setup Menu, sub menu System Control In the Advanced Setup Menu, sub menu Furnace In the Advanced Setup Menu, sub menu AC/HP In the Scheduling Menu Question Title * 19. When testing resistances of ECM or Inverter driven motor windings, you want to see what? Less than 18k ohms Exactly the ohm values listed in the manuals C-S plus C-R equals R-S 3 equal resistances Question Title * 20. If a circuit board gets changed in a fully communicating system, you must (select all that apply) Complete a Full Installation through the Infinity/Evolution controller Make a return visit to recalibrate the system Move the model plug to the new board Put the old board in another piece of equipment Question Title * 21. Completing the Full Installation through the controller is an advisable course of action during many control related service calls True False Question Title * 22. If you used Check Out Mode to enable Heat Pump Heating and outside temps are over the max heating OAT, will the unit run? Yes No Question Title * 23. Pump down is a feature in the Evolution Control that is required, if pump down operation is desired True False Question Title * 24. Questions 25-39 pertain to the 5 stage 189/288 models, do you understand Yes Question Title * 25. Max equivalent line length allowed is 100 ft 250 ft 50 ft 200 ft Question Title * 26. Long Line accessories are required at what equivalent length 80 ft 200 ft 100 ft No Long Line Accessories are required Question Title * 27. This product is qualified for Low Ambient Cooling True False Question Title * 28. Minimum outdoor temp for heating is -15 -22 10 32 Question Title * 29. What type of compressor is used in this equipment Semi Hermetic Scroll Reciprocating Rotary Question Title * 30. If controlled by a conventional thermostat, the minimum outdoor temp for cooling is 10 40 55 80 Question Title * 31. If controlled by an Evolution control, the minimum outdoor temp for cooling is 55 80 40 10 Question Title * 32. Maximum outdoor heating temperature is 125 55 66 115 Question Title * 33. The control panel consists of (select all that apply) Contactors The AOC (communicating board) Disconnect fuses The Inverter (VFD) Question Title * 34. These units contain a Discharge Temperature thermistor True False Question Title * 35. These units contain a Discharge Pressure Transducer True False Question Title * 36. The crankcase heater is a replaceable component True False Question Title * 37. All codes will always blink on the AOC board True False Question Title * 38. The SEER rating of this equipment is 22 for AC only and 20 for Heat Pump 19 for AC only and 18 for Heat Pump Varies on location Not listed Question Title * 39. This equipment can calculate Superheat and Subcooling True False Question Title * 40. Questions 41-55 pertain to the Fully Modulating 186/284, do you understand? Yes Question Title * 41. Can this equipment be ran permanently with a conventional thermostat? Yes No Question Title * 42. This equipment has a Discharge Temperature Thermistor True False Question Title * 43. This equipment has a Discharge Pressure Transducer True False Question Title * 44. This equipment only comes with a Rotary Compressor True False Question Title * 45. One difference between the 5 ton and other sizes is It has a Braze Plate Heat Exchanger You must wire it backwards The noise is reduced The condenser fan is a different design Question Title * 46. What are the lineset length rules (select all that apply) Max Actual Length of 200 ft Long Line Accessories required after 80 ft Liquid Line Service Valve on Heat Pumps for long line Max Equivalent Length of 250 ft Question Title * 47. What is the SEER rating of the equipment 42 26 for AC only and 24 for Heat Pump 19 for AC only and 18 for Heat Pump 18 for AC only and 19 for Heat Pump Question Title * 48. The Bluetooth module (select all that apply) Can be accessed by anyone Can show recent faults Can change settings Can observe operation of the equipment Can only be accessed by Carrier/Bryant Dealers Can update firmware for the outdoor board Question Title * 49. How many digits are the Alert Codes 2 digits based on blinking lights 3 digits There are no digits, only descriptions 4 digits; a 2 digit Base Code and a 2 digit Malfunction or Fault code Question Title * 50. Minimum outdoor temp for heating is -22 32 -15 10 Question Title * 51. The Maximum outdoor temp in heating is 55 125 66 75 Question Title * 52. The Maximum outdoor temp in cooling is 55 66 75 125 Question Title * 53. This product is qualified for Low Ambient Cooling True False Question Title * 54. The control box consist of (select all that apply) PCM (Primary Control Module) Reactor(s) Noise Filter Board VFD Bluetooth Module Question Title * 55. The crankcase heater is a replaceable component True False Submit