Bryant Variable Speed Certification Question Title * 1. Register Question Title * 2. Questions 3-12 relate to GENERAL Bryant equipment and general refrigeration principles. Do you understand? Yes Question Title * 3. Long line accessories are required when equivalent line length exceeds how many feet? 200 80 250 100 Question Title * 4. Factory condensing units come charged for how many equivalent feet of lineset 250 ft 0 ft 25 ft 15 ft Question Title * 5. When installing a Heat Pump, the filter drier must be Turned upside down Valved off Biflow Unidirectional Question Title * 6. When installing a Liquid Line Solenoid Valve for a Heat Pump, the solenoid Must be a smaller pipe size Mounts at the Indoor Coil Must be a larger pipe size Mounts within 2 ft of the outdoor unit Question Title * 7. EXVs are what? Another way of saying solenoid Not important Motor driven metering devices Another way of saying TXV Question Title * 8. To charge by subcooling, outdoor ambient temperatures must be At 0 Between 65 and 105 Less than 65 or greater than 105 Below 0 Question Title * 9. To charge by subcooling, the indoor ambient temperatures must be At 0 Room temperature Between 65 and 80 Below 0 Question Title * 10. If temperatures are inadequate for charging by subcooling You can let the system run regardless of charge You cannot run or add refrigerant to the equipment at all You must cover the equipment until you return You should charge by lineset length and return when temperatures are adequate Question Title * 11. If you were choosing to size a unit to the heating load or to the cooling load, what else must you consider Only the Manual J calculation for the home How much money the customer wants to spend on accessories The ductwork limitations How many people live in the house Question Title * 12. Additional refrigerant charge is listed as Simply based on subcooling 0.6 oz/ft, but should be double checked 1 extra pound per 10 ft Simply based on superheat Question Title * 13. Questions 14-23 pertain to current Evolution Systems, do you understand Yes Question Title * 14. Communication wire from the air source to the outdoor unit uses B, D A, B, and sometimes C A, B, C, D C, D Question Title * 15. The manuals will tell you to wait 10 minutes after power down before handling the circuitry, why? The AC voltage charges capacitors at a higher voltage than your meter reads at the incoming lugs. So the capacitors need time to drain Since AC voltage flows both ways on a wire, you have to wait for the opposite direction to flow out You don't, the factory is just making rules Not all disconnects work correctly and powering down for 10 minutes will trip a breaker if something is wrong Question Title * 16. The PEV does what? Prevent the system from running when the pressures are equal Soft start the compressor Keep refrigerant pressures isolated from low to high sides Equalizes the pressures from the low and high sides Question Title * 17. The purpose of Check Out Mode is to Establish communication to the whole system Lock the system permanently into modes so others may be disabled Establish communication between the indoor and outdoor units Briefly run all components to observe operation in requested modes Question Title * 18. Altitude adjustments are located in which Setup control menu In the Advanced Setup Menu, sub menu System Control In the Advanced Setup Menu, sub menu Furnace In the Advanced Setup Menu, sub menu AC/HP In the Scheduling Menu Question Title * 19. When testing resistances of ECM or Inverter driven motor windings, you want to see what? Less than 18k ohms 3 equal resistances C-S plus C-R equals R-S Exactly the ohm values listed in the manuals Question Title * 20. If a circuit board gets changed in a fully communicating system, you must (select all that apply) Put the old board in another piece of equipment Move the model plug to the new board Make a return visit to recalibrate the system Complete a Full Installation through the Infinity/Evolution controller Question Title * 21. Completing the Full Installation through the controller is an advisable course of action during many control related service calls True False Question Title * 22. If you used Check Out Mode to enable Heat Pump Heating and outside temps are over the max heating OAT, will the unit run? Yes No Question Title * 23. Pump down is a feature in the Evolution Control that is required, if pump down operation is desired True False Question Title * 24. Questions 25-39 pertain to the 5 stage 189/288 models, do you understand Yes Question Title * 25. Max equivalent line length allowed is 250 ft 50 ft 200 ft 100 ft Question Title * 26. Long Line accessories are required at what equivalent length No Long Line Accessories are required 200 ft 100 ft 80 ft Question Title * 27. This product is qualified for Low Ambient Cooling True False Question Title * 28. Minimum outdoor temp for heating is -15 32 10 -22 Question Title * 29. What type of compressor is used in this equipment Rotary Semi Hermetic Scroll Reciprocating Question Title * 30. If controlled by a conventional thermostat, the minimum outdoor temp for cooling is 80 10 55 40 Question Title * 31. If controlled by an Evolution control, the minimum outdoor temp for cooling is 55 40 80 10 Question Title * 32. Maximum outdoor heating temperature is 115 125 55 66 Question Title * 33. The control panel consists of (select all that apply) Contactors The AOC (communicating board) The Inverter (VFD) Disconnect fuses Question Title * 34. These units contain a Discharge Temperature thermistor True False Question Title * 35. These units contain a Discharge Pressure Transducer True False Question Title * 36. The crankcase heater is a replaceable component True False Question Title * 37. All codes will always blink on the AOC board True False Question Title * 38. The SEER rating of this equipment is 19 for AC only and 18 for Heat Pump Varies on location Not listed 22 for AC only and 20 for Heat Pump Question Title * 39. This equipment can calculate Superheat and Subcooling True False Question Title * 40. Questions 41-55 pertain to the Fully Modulating 186/284, do you understand? Yes Question Title * 41. Can this equipment be ran permanently with a conventional thermostat? Yes No Question Title * 42. This equipment has a Discharge Temperature Thermistor True False Question Title * 43. This equipment has a Discharge Pressure Transducer True False Question Title * 44. This equipment only comes with a Rotary Compressor True False Question Title * 45. One difference between the 5 ton and other sizes is You must wire it backwards The noise is reduced The condenser fan is a different design It has a Braze Plate Heat Exchanger Question Title * 46. What are the lineset length rules (select all that apply) Max Actual Length of 200 ft Long Line Accessories required after 80 ft Max Equivalent Length of 250 ft Liquid Line Service Valve on Heat Pumps for long line Question Title * 47. What is the SEER rating of the equipment 26 for AC only and 24 for Heat Pump 18 for AC only and 19 for Heat Pump 19 for AC only and 18 for Heat Pump 42 Question Title * 48. The Bluetooth module (select all that apply) Can change settings Can show recent faults Can observe operation of the equipment Can update firmware for the outdoor board Can be accessed by anyone Can only be accessed by Carrier/Bryant Dealers Question Title * 49. How many digits are the Alert Codes 4 digits; a 2 digit Base Code and a 2 digit Malfunction or Fault code There are no digits, only descriptions 3 digits 2 digits based on blinking lights Question Title * 50. Minimum outdoor temp for heating is -22 -15 32 10 Question Title * 51. The Maximum outdoor temp in heating is 75 125 66 55 Question Title * 52. The Maximum outdoor temp in cooling is 75 125 55 66 Question Title * 53. This product is qualified for Low Ambient Cooling True False Question Title * 54. The control box consist of (select all that apply) PCM (Primary Control Module) Reactor(s) Noise Filter Board VFD Bluetooth Module Question Title * 55. The crankcase heater is a replaceable component True False Submit